How much electricity does a ceramic kiln use?

Request information

The energy consumption of an electric ceramic kiln is one of the factors to consider before buying, especially if you fire regularly. There is no single figure: the consumption of a firing depends on the kiln’s power, the final temperature, the length of the cycle, the load and the quality of the insulation. It can, however, be estimated with a simple calculation.

Installed power and actual consumption

Installed power, expressed in kW, indicates the kiln’s maximum draw when all the heating elements are on. During a firing, however, the elements are not on all the time: the controller switches them on and off to follow the programmed schedule. During slow ramps and holds they work only part of the time; close to the top temperature they work for longer.

Actual consumption is therefore always lower than installed power multiplied by the total length of the cycle.

How to estimate the consumption of a firing

A conservative estimate is obtained by multiplying installed power by the hours the heating elements are actually on:

consumption (kWh) = power (kW) × hours of actual operation

Purely as an example, a 2.5 kW kiln whose elements stay on for a total of 4 hours uses about 10 kWh. Multiplying this value by the energy price on your bill gives the cost of the firing. The real figure should be checked case by case: some users measure consumption with a dedicated meter or by reading the meter before and after firing.

Factors affecting consumption

Final temperature

Heat losses increase with temperature: a firing at 1250 °C uses considerably more energy than a third firing at 800 °C, even for the same duration.

Insulation

High-density ceramic fibre stores little heat and loses little to the outside, so it reduces the energy needed to heat the chamber. Refractory brick has a greater thermal mass: it absorbs more energy during heating, but gives thermal stability in return. The differences are described in the article on fibre or refractory bricks.

Firing schedule

Very slow ramps and long holds lengthen the cycle and increase total consumption. They are necessary for some pieces, but should be tailored to the real needs of the clay body and glaze.

Load

A full kiln uses only slightly more energy than a half-empty one, but spreads the consumption over a larger number of pieces. The cost per piece is therefore lower when the kiln is fully loaded.

Kiln size

A kiln that is oversized for your output means heating a larger volume than necessary. Choosing the right capacity is one of the most effective ways to keep consumption down over time.

How to reduce the cost of each firing

  • Fire full loads, using kiln shelves and props to make use of the full chamber height.
  • Avoid holds and ramps longer than necessary.
  • Let the kiln cool with the door closed: as well as protecting the pieces, it uses no energy.
  • Schedule firings during the cheapest time bands, if your tariff allows it.
  • Keep the kiln in good working order: worn heating elements lengthen heating times. The tutorial on replacing the heating elements shows how to do it.

Power ratings of Faber kilns

As a reference, Faber kilns start at about 2.5 kW for the 40 litre FBL40, rising to 2.8 kW for the FBL70 and 3.1 kW for the FBL85, up to 8 kW for the FBL270. FBL series kilns use high-density ceramic fibre insulation designed to keep energy consumption low. For questions about your electricity supply and installation, see the guide to 230 V ceramic kilns.

    You may also like

    All articles